# Finite Different Method Demo Tutorial Test the software with the following inputs (Navarro et al., 2012): - Spatial discretization: dx = 0.5 m; - Time discretization: dt = 1/8000 s; - Recording total time: T = 2.0 s; - Room dimension: 8.0 m x 8.0 m x 8.0 m; - Absorption Coefficient surface i: 1/6 ≈ 0.17; - Air absorption: 0.0 1/m; - Absorption term: A_{M}; - Source On time: S = 1.0 s; - Source position coordinates: 4.0, 4.0, 4.0; - Receiver position coordinates: 2.0, 2.0, 2.0; Test if the software provides the following results (Navarro et al., 2012): - Reverberation time (RT): 1.18 s; - Early Decay Time (RDT): 1.18 s; - Clarity (C_{80}): 2.08 dB; - Definition (D_{50}): 45.63 % - Centre Time (T_{s}): 85.33 ms